Medical electrical equipment - Part 2-85: Particular requirements for the basic safety and essential performance of cerebral tissue oximeter equipment
文件核验信息(付费前可核对)
标准范围(官方英文摘要)
This document applies to basic safety and essential performance of cerebral tissue oximeter equipment, that employs light at multiple wavelengths to derive a quantitative measure of oxygen saturation of haemoglobin within the volume of tissue sampled under the probe attached to the head. The cerebral tissue oximeter equipment can be based on continuous light, frequency domain or time domain technologies. This document applies to ME equipment used in a hospital environment as well as when used outside the hospital environment, such as in ambulances and air transport. Additional standards may apply to ME equipment for those environments of use.
NOTE 1 Cerebral tissue oximeters are sometimes referred to as near infrared spectroscopy equipment in medical literature.
Not included within the scope of this document are:
- invasive tissue or vascular oximeters;
- oximeters that require a blood sample from the patient;
- equipment measuring dissolved oxygen;
- ME equipment, or part thereof, that measures path-length-dependent haemoglobin change. The requirements for functional near-infrared spectroscopy equipment are found in ISO 80601-2-71[4];
- ME equipment, or part thereof, that m
标准信息
- 标准号
- ISO 80601-2-85:2021
- 英文标题
- Medical electrical equipment - Part 2-85: Particular requirements for the basic safety and essential performance of cerebral tissue oximeter equipment
- 发布单位
- —
- 技术委员会
- TC 62/SC 62D
- 版本 / 版次
- 1.0
- 状态
- 现行
- 发布日期
- 2021
- ICS 分类
- 11.040.10 麻醉、呼吸和复苏设备
- 页数
- 107 页
- 官方定价
- CHF 216
同分类下的其他标准
相关标准
怎么获取 ISO 80601-2-85:2021 全文
这份标准属于 ISO/IEC 发布,全文 107 页,语言为 EN。如果你只需要核对条款、做合规对照或者写方案引用,直接在线支付 5 元即可获得 PDF 全文,支付成功后立即给出下载链接(24 小时内有效,之后凭购买记录也能随时重新下载,不再收费)。
如果你要长期、大量使用这类标准,包年会员更合适:39 元一年每天可下 10 份,69 元一年每天 50 份,999 元一年不限次数。会员下载过的标准可以随时免费重下,不占用每日次数。按单份均价 3 元估算,一年下 13 份以上就已经回本。
需要注意的是,标准正文的著作权归 ISO、IEC 及各国家成员体所有。本站提供的是文献检索与代传服务,建议在正式项目、投标或认证场景中同时通过官方渠道核验标准的最新版本,避免使用已废止版本造成合规风险。